Evaluation using LDCT IQA

Prerequisite

This example assumes you have:

  1. the package ldct-benchmark installed
  2. the LDCT dataset downloaded to a folder path/to/ldct-data
  3. The environment variable LDCTBENCH_DATAFOLDER set to that folder

Please refer to Getting Started for instructions on how to do these steps.

Besides the standard full-reference IQA metrics (SSIM, PSNR, VIF), we also support evaluation using a specialized model for no-reference perceptual image quality assessment of low-dose CT images. This model was the winning entry (agaldran1) of the Low-dose Computed Tomography Perceptual Image Quality Assessment Grand Challenge 20232 which was organized in conjunction with MICCAI 2023.

The aim of the challenge was to develop no-reference IQA methods that correlate well with scores provided by radiologists. To this end, the organizers generated a total of 1500 (1000 train, 200 val, 300 test) images of various quality by introducing noise and streak artifacts into routine-dose abdominal CT images. Resulting images were rated by radiologists on a five-point Likert scale and their mean score was used as the ground truth.

The five-point Likert scale was defined as follows (see Table 1 in the paper2):

Numeric score Verbal descriptive scale Diagnostic quality criteria
0 Bad Desired features are not shown
1 Poor Diagnostic interpretation is impossible
2 Fair Images are suitable for limited clinical interpretation
3 Good Images are suitable for diagnostic interpretation
4 Excellent The anatomical structure is evident

Given some CT image, the model predicts a score in the range [0, 4] (with increments of 0.2) on above scale.

Use with out-of-distribution (OOD) data

Be aware that any evaluation using this model will most likely be an OOD setting and predicted scores should be interpreted with caution. The model was

  • trained only using abodminal CT images. However, the paper2 performs some experiments using a clinical head CT dataset, to evaluate the methods generalization capabilities.
  • trained on four distinct noise levels only. These noise levels may not be representative of your data.
  • not trained on denoised images at all. It has only seen routine-dose images and various distorted versions thereof. It remains unclear how well the model generalizes to denoised images.

Evaluate DICOMs using the LDCTIQA model

Let's evaluate a routine-dose and low-dose abdominal CT scan from the LDCT dataset using this LDCTIQA model (see ldctbench.evaluate.ldct_iqa.LDCTIQA for more details).

# Import libraries
import os
from importlib.resources import files

import numpy as np
import pydicom

from ldctbench.evaluate import LDCTIQA
from ldctbench.utils import load_yaml

# Get abdominal patient from test set
info = load_yaml(files("ldctbench.data").joinpath("info.yml"))
patient = info["test_set"][5]

# Setup model
ldctiqa = LDCTIQA()

# Evaluation function
def evaluate_dicom(folder):
    res = []
    for f in os.listdir(folder):
        file = os.path.join(folder, f)
        if pydicom.misc.is_dicom(file):
            ds = pydicom.filereader.dcmread(file)
            img = ds.pixel_array.astype("float32")
            score = ldctiqa(img)
            res.append(score.item())
    return res

# Evaluate on low-dose and high-dose images
for scan, dose in [("input", "low"), ("target", "high")]:
    scores = evaluate_dicom(
        folder=os.path.join(os.environ["LDCTBENCH_DATAFOLDER"], patient[scan]),
    )
    print(
        f"LDCTIQA for {dose}-dose scan of {patient['id']}: {np.mean(scores):.2f} ± {np.std(scores):.2f}"
    )
Running this script will give us the following scores for the routine-dose and low-dose images of patient L241:

Dose level LDCTIQA score
Low 2.55 ± 0.44
High 4.0 ± 0

According to our model, this low-dose scan has an image quality between "Fair" and "Good", while the high-dose scan is rated as "Excellent".

We also provide a function (ldctbench.evaluate.evaluate_dicom) to evaluate a single DICOM file or a folder of DICOM files and store the results in a json file (if the savedir argument is provided). This function can be used as follows:

import numpy as np
from ldctbench.evaluate import evaluate_dicom
scores = evaluate_dicom(dicom_path="path/to/dicom/series", savedir="path/to/save")
print(f"Evaluated {len(scores)} files. LDCTIQA = {np.mean(scores):.2f} ± {np.std(scores):.2f}")
>>> Evaluate DICOM(s): 100%|██████████████████| 137/137 [00:11<00:00, 12.27it/s]
>>> Saved scores to path/to/save/scores.json
>>> Evaluated 137 files. LDCTIQA = 3.96 ± 0.08

Evaluate denoising methods using the LDCTIQA model

We can also evaluate the performance of denoising methods using the LDCTIQA model. Let's evaluate the performance of the CNN-10 model on the test set of the LDCT dataset.

Running

ldctbench-test --methods cnn10 --metrics LDCTIQA --print_table
will give us the following results:

Method LDCTIQA (Chest) LDCTIQA (Abdomen) LDCTIQA (Neuro)
LD 0 3.208 3.965
cnn10 3.296 3.998 3.972

We find that on all three anatomies, the CNN-10 model improves over the LD baseline in terms of LDCTIQA score and provides a rating between "Good" and "Excellent" for all anatomies. However, for the neuro scans the improvement is marginal. Note that results on chest and neuro scans should be interpreted with caution, as the model was trained on abdominal CT images only!


  1. Official GitHub repository of agaldran: https://github.com/agaldran/ldct_iqa

  2. Lee, Wonkyeong, Fabian Wagner, Adrian Galdran, Yongyi Shi, Wenjun Xia, Ge Wang, Xuanqin Mou, et al. 2025. “Low-Dose Computed Tomography Perceptual Image Quality Assessment.” Medical Image Analysis 99 (January):103343. https://doi.org/10.1016/j.media.2024.103343